What is the cost of 250 kVA transformer?
270000/-
Ask any question you have in mind. We will be happy to answer.
Description | Transformer Prices |
---|---|
250 KVA | 270000/- |
400 KVA | 335000/- |
500 KVA | 450000/- |
1000 KVA | 695000/- |
What is the current rating of 250 kVA transformer?
calculation of current rating of distribution transformer–
ex– for 250 kva transformer=325/25=13 amp.
How many houses can a 100 kVA transformer supply?
8 – 500 kVA connects a nominal number of 103 customers, 100 kVA connects 14 customers. I guess the difference in houses/kVA is due to the load becoming less normal with fewer people on it. In India the default permission to the domestic user is 3 KWs.
What is the cost of 500 kVA transformer?
3-Phase 500 kVA Oil Cooled Distribution Transformer at Rs 535000 in Bathinda.
How much does a 250 kVA transformer weight?
1-2. 33kV – 400/230V
Item | Capacity | Total weight |
---|---|---|
kVA | kg | |
2 | 100 | 800 |
3 | 160 | 990 |
4 | 250 | 1450 |
What is the price of 200 kVA transformer?
market price of 200 Kva Transformers in India is Rs 1.6 Lakh/ Piece.
How many amps can a 250 kVA transformer handle?
The transformer rating is expressed in both KVA and Voltage. For example, you have a 250 KVA 3-phase transformer rated at 11kv/415v. The primary full-load current is 13,121.982 A, and the secondary full-load current is 347.812 A.
How many amps can a 300 kVA transformer handle?
1,000 Amps
The 300 KVA transformer itself can handle up to 300,000 volts and 1,000 Amps.
How much kVA is required for a house?
The KVA of a generator required to run your home comfortably; For an average home, the required KVA should be at least 3 KVA to 5 KVA. With this power in a generator, you will comfortably be able to run all your household appliances. This includes your ACs and Fridge, as well as other items that use a heavy duty point.
How many amps can a 500 kVA transformer supply?
The nameplate rating says it’s a 500 KVA transformer it has 400v phase to phase and has 721.6 A.
How many amps can a 300 kva transformer handle?
What is a 500 kva transformer?
The 500kVA transformer plays the role of converting electrical energy in the power distribution system and is usually installed in the end-use area for residential lighting, industrial production, etc.
How do I know what size cable I need for my transformer?
For Transformer, we should choose two types of cable such as the primary side and secondary side. The rating of the cable should be 150% of the full load current. i.e if your transformer’s primary current is 450 Amps means, you should choose 450 *150% = 675 Amps capacity size cable.
How do you calculate the maximum load of a transformer?
How to calculate transformer load capacity
- Obtain the transformer kVA rating.
- Get your load’s required voltage.
- Rearrange the kVA equation to leave the current on one side and our parameters on the other. Resulting in: I = 1000 ⋅ kVA V I= \frac{1000 \ \cdot \ \text{kVA}}{V} I=V1000 ⋅ kVA.
- Plug in the data and solve!
How many amps can a 200 kVA transformer handle?
So, with this formula, we could manipulate it to get the number of amperes that a 200kVA transformer would be able to handle. The final answer will be 288.68 amperes if it is a 3-phase transformer and 833.33 amperes if it is a single-phase transformer.
How do I choose a transformer size?
How to Size a Transformer
- Transformer size is determined by the kVA of the load.
- Load voltage, or secondary voltage, is the voltage needed to operate the load.
- Line voltage, or primary voltage, is the voltage from the source.
- Single-Phase has two lines of AC power.
How do I work out what size transformer I need?
Since you know kVA = V * l / 1,000, we can solve for V to get V = kVA * 1,000 / l. So you’ll multiply your kVA rating by 1,000 and then divide by the amperage. If your transformer has a kVA rating of 75 and your amperage is 312.5, you’ll plug those numbers into the equation — 75 * 1,000 / 312.5 = 240 volts.
How many amps is a 250 kVA generator?
Ashok Leyland 250 kVA Three Phase Generator Set, Current: 348 amp.
How many amps is a 225 kVA transformer?
Three Phase Transformers, Full Load Amperes (FLC) | ||
---|---|---|
KVA | 208V | 480V |
112.5 | 312 | 135 |
150 | 416 | 180 |
225 | 624 | 270 |
How many kVA do I need for a 4 bed house?
The average demand usually works out around 80-100 amps once diversity is taken no account, in a modern 3-4 bedroom home (18.4 – 23 kVA).
How much kVA does a AC use?
High Wattage and High Initial Current
Tonnage | Max Wattage | Max kVA (assuming 0.85 power factor) |
---|---|---|
1 Ton | 1300 Watts or 1.3 kW | 1.6 kVA |
1.5 Ton | 1900 Watts or 1.9 kW | 2.4 kVA |
2 Ton | 2500 Watts or 2.5 kW | 3 kVA |
What is thumb rule in electrical?
Thumb Rules. Cable Capacity. For Cu Wire Current Capacity (Up to 30 Sq.mm) = 6X Size of Wire in Sq.mm. Ex. For 2.5 Sq.mm = 6×2.5 = 15 Amp, For 1 Sq.mm = 6×1 = 6 Amp, For 1.5 Sq.mm = 6×1.5 = 9 Amp.
What is the cable size for kVA transformer?
So the minimum cable size has to be at least 63 square millimetres (nearest commercially available size is 70 mm².) All cables, even for 20 amp load, that originate from the main switchboard near a 200 kVA transformer have to be at least 70 mm² because of the potential short circuit current..
How much load can a 500 kVA transformer handle?
Usually, the load rate of the distribution transformer should be 70% to 85%. Therefore, from a safety point of view, the actual power that a 500KVA transformer can drive is 280kw-340kw.
How much load can a 100 kVA transformer handle?
100 KVA transformer load capacity in kW
2, with the average power factor of 0.8 calculation,a 100 KVA transformer can provide (100 KVA × 0.8) 80 KW active power for the load.